LaCie 12big Rack Fibre 8 System Overview
User Manual page 10
1.3.1. Bay Identification
The bay identification graphic is provided to assist with proper instal-
lation and location of components (Fig. 04).
Either RAID Controllers or Disk I/O Modules are installed in I/O
Module Bay’s #0 and #1. Bay #0 is the primary and Bay #1 is the
secondary. If only one module is installed, then a Blank I/O module
must be installed into the secondary (lower) empty bay. All PCM bays
must be populated. No bay will be left empty.
IMPORTANT INFO: Do not mix RAID Controllers and Disk I/O
Modules in the same enclosure.
1.3.2. Enclosure Drive Slots
The chassis assembly contains 12 drive slots located at the front of the
enclosure, each of which accommodates the appropriate plug-in drive
carrier module. A drive slot is defined as the space required to house a
single 1.0” high 3.5 inch disk drive in its carrier module. The 12 drive
slots are arranged in a 3 row by 4 column configuration.
Refer to 2.2.1. Enclosure Drive Slot Number Convention and 2.2.2.
Drive Location Rules for illustrated examples of the drive slot number-
ing and applicable rules for drive type installation. Expansion enclosure
drive slot numbering will pickup after the last numbered slot of the RAID
enclosure and continue incrementally to the maximum number. For ex-
ample, the rst Expansion enclosure slots will be numbered 13 - 24 and
the second enclosure slots numbered 25 - 36, and so forth until the
maximum number of drives (96) is reached.
1.3.3. Operator’s Panel
The front of the 12big Rack Fibre 8 enclosure incorporates
an Operator’s (OPS) panel with three LEDs and the Unit ID
LCD display (Fig. 05). The OPS panel provides the user with
a consolidated view of the operational status of the enclosure
components and the enclosures assigned ID. Please refer to
1.3.4. Visible Alarms - OPS LEDs for details of the LED status condi-
tions.
1.3.3.1. Audible Alarms
Audible alarms are provided as part of the notification system which
can be muted via the OPS panel or StorView Storage Management
software. Refer to 4.3. Audible Alarm for details on the different
alarm states and their meanings.
1.3.3.2. Mute Button
The OPS panel button offers the option to silence the audible alarm.
Fig. 04 - Enclosure Bay Identification
Fig. 05 - OPS Panel